Pump Electrical Schematic |
| 3 Phase 240/480VAC.60HZ |
Correct rotation is counter clockwise as viewed from the motor's fan end. |
![]() |
||
|
|
||||
| OPERATION |
NOTES |
|||
|
NOTE 1: | 120V continuous; capable of supplying 1.5 amps for the pump's control circuitry and any load associated with solenoids, contactors, etc. See exception in Note 3. | ||
| NOTE 2: | The master "CALL" relay controls the system by making or breaking the 120V source referred to in Note 1. The input (M code) to the master "CALL" relay is either 18-36 VAC/DC or 120V as specified by the customer. A bleeder resistor (15k-2w) is installed across the 120V relay's input to assure turn-off. | |||
| NOTE 3: | If the source of the "CALL" meets the requirements of Note 1 (i.e. not a typical CNC controller), install Jumper (J1) and connect the "CALL" directly to 120V and Neutral on the terminal strip. | |||